One of the following icons will appear in the bottom left corner of the Main screen (A).

Information

Reminder

Error – normal error or warning

Error – spa will not function until fixed
If a message has a clear button (D), the message may not go away until a certain condition is met. For example, the water temperature in the heater may need to change before a message will clear.
Follow these steps to view the message:
1 – A message may appear automatically. If so, skip to step 3.
2 – Go here (A) to view the message (C).
3 – Exit the screen (B or D).
GENERAL MESSAGES
Message:
Priming Mode
Each time the spa is powered up, it will enter Priming Mode. The purpose of Priming Mode is to allow the user to run each pump and to manually verify that the pumps are primed (air is purged) and water is flowing. Priming Mode lasts 4 minutes but you can exit it earlier by pressing any Temp button. The heater is not allowed to run during Priming Mode. NOTE: If your spa has a circulation pump, you can turn it ON by pressing the LIGHT button during Priming Mode.
Message:
Possible freezing condition
The water has reached a temperature in which a potential freeze condition is possible. Pumps will turn On and Off to circulate water and the heater may also activate until a warmer temperature is reached.
Message:
Configuration error
A software conflict has been detected and the spa is disabled. Please contact your dealer or service provider.
Message:
- - - F or - - - C
This is displayed on a system startup when the software has not yet detected a temperature reading (view page 6). It is also displayed when the system has not detected a temperature for over 60 minutes which can occur if the M8 feature was activated.
Message:
Set the time
Set the time of day to ensure proper timing of filter cycles.
Message:
The water level is too low
On a system equipped with a water level sensor, it has detected the water level to be below the sensor. The pump(s) and heater are disabled. Once the water level has been restored above the sensor, the pump(s) and heater will be enabled and the message will disappear.
Message:
The water is too hot
While the circulation pump was running, the system detected a water temp of 110°F (43°C) and spa functions were disabled. The system will automatically reset when the water temp is below 108°F (42°C).
Message:
Drain Mode
Message:
Hold (aka Standby) Mode
HEATER-RELATED MESSAGES
Message:
The water flow is low
Insufficient water flow through the heater has been detected during a heating cycle. The heater will try again in 1 minute.
Message:
The water flow has failed
Insufficient water flow through the heater has been detected during a heating cycle multiple times and the heater has been disabled. After the problem has been resolved, the user must clear the message.
Message:
The heater is dry
The heater failed to start several times due to lack of water flow through the heater. The message must be cleared in order for the system to try to heat again.
Message:
The heater may be dry
The heater failed to start due to lack of water flow through the heater. The system will try to heat again in approximately 15 minutes.
Message:
The heater is too hot
The system has detected a water temp of 118°F (48°C) and the spa functions were disabled. Once the water is below 108°F (about 42°C), the user must reset the message.
SENSOR-RELATED MESSAGES
Message:
Sensors are out of sync
The heater’s temperature sensors are out of sync and the heater is now inoperable. Please contact your dealer or service provider.
Message:
Sensors are out of sync
The heater’s temperature sensors have been out of sync for an extended period of time. Please contact your dealer or service provider.
Message:
Sensor A fault
Temperature sensor A or its’ circuit has failed and the spa’s functions have been disabled. Contact your dealer or service provider.
Message:
Sensor B fault
Temperature sensor B or its’ circuit has failed and the spa’s functions have been disabled. Contact your dealer or service provider.
Message:
Run Jets 1 to get temperature
MAINTENANCE MESSAGES
Message:
Check Ozone
This message may appear every 360 days. Check your ozone and/or UV generator per your spa manufacturer’s instructions.
Message:
Service Check-Up
This message may appear every 365 days. Contact your service organization for a service check.
Message:
Change the filter
The heater’s temperature sensors have been out of sync for an extended period of time. Please contact your dealer or service provider.
Message:
Clean the filter
This message may appear every 30 days. Clean the filter media as instructed by the manufacturer.
Message:
Change the water
This message may appear every 90 days. Change the water in the spa on regular basis to maintain proper chemical balance and sanitary conditions.
Message:
Check the sanitizer
This message may appear every 7 days. Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals.
Message:
Check the pH
This message may appear every 7 days. Check sanitizer level and other water chemistry with a test kit and adjust with the appropriate chemicals.
Message:
Change UV
Message:
Check the filter now
TECHNICAL MESSAGES
Message:
Test the GFCI
This message may appear every 30 days. The Ground Fault Circuit Interrupter (GFCI) or Residual Current Device (RCD) is an important safety device and must be tested on a regular basis to verify its reliability. Every user should be trained to safely test the GFCI or RCD associated with the hot tub installation. A GFCI or RCD will have a TEST and RESET button on it that allows a user to verify proper function.
Warning: If freezing conditions exist, a GFCI or RCD should be reset immediately, or spa damage could result. If the GFCI or RCD does not reset and freezing conditions exist, drain the spa of all water until the spa is functional again. The end user should test and reset the GFCI or RCD on a regular basis.
Message:
The GFCI test failed
NORTH AMERICA ONLY: The system has detected that there may be a problem with your GFCI and/or its’ installation creating a potential safety issue. Contact a local licensed electrician.
Message: BT Failure
Message:
Hot fault (Call for service)
The system has detected a potential stuck pump relay. DO NOT ENTER THE WATER as the water may be too hot. Turn the breaker off and back on to reset.
Message:
The clock has failed
The clock that keeps track of time when the spa is powered Off has failed. Contact your dealer or service provider.
Message:
Program memory failure
The clock that keeps track of time when the spa is powered Off has failed. Contact your dealer or service provider.
Message:
J29
Recycle the spas’ power. If this message appears after several power-ups, contact your dealer or service provider.
Message:
The settings have been reset
Message:
Communications error
(Call for service)
The control panel is not receiving communication from the control system and thus inoperable. Please call your dealer or service provider. Please note that this can briefly appear during a system start-up but should quickly disappear.