PERFORM GFCI TEST

Note: GFCI test applies to North America only. This feature is not available on CE rated systems.

Follow these steps to perform a GFCI test:

1 – Go to the Main menu, Settings, Diagnostics (A), GFCI Test (B) to view the GFCI Test screen (C).*

2 – Go to GFCI Test(D) and press the SELECT navigation button to perform the test.

3 – View the GFCI Status (E).

If the GFCI Test status is “Passed” (G), you may not need to perform this test. This test cannot be performed without resetting the GFCI first (F).

If the GFCI Test status is “Armed” (E), proceed to the next step.

4 – Press the SELECT navigation button to perform the test. Within approximately 12 seconds, one of the following tow things will happen:

1 – The spa powers Off. After the spa powers Off, go to the GFCI and power On the spa. When the spa is powered On, it goes into Priming Mode. When Priming Mode is complete, navigate to the GFCI Test screen and confirm that it says “GFCI Status – Passed” (G).

2 – A “GFCI Test Failed” message appears. In this case, contact a qualified service technician. While you wait for the spa technician to arrive, the spa can be run normally for a time by cycling the power.

Reset Button: The most common use of Reset (F) is when moving the spa to a new location. Using Reset (F) forces a new Test to be performed at the new location.